<LOGO>
FM Transmitter Measurement Report
Created: 2026-04-09 18-05-22
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 35 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 5.1 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
16 kHz 69 kHz 4055 0,5672
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,9 dBr 5,48 dBr 6,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 69 kHz MIN: 16 kHz % above 76 kHz: 0,5672 Acquired: 2026/04/09 18.04.17 Total samples: 4055 Equivalent time: 0:03:22 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300
FM Scope MAX: 6,0 dBr MIN: 3,9 dBr AVE: 5,48 dBr % above 12,2 dBr: 0,0 Last value: 4,2 dBr (2026/04/09 18.04.17) 17.50 17.52 17.54 17.56 17.58 18.00 18.02 18.04 0 2 4 6 Pm [dBr]